وبلاگ بلیان

Design of Latticed Steel Transmission Structures (ASCE 10-97).: General; Chapter 2 Loading, Geometry, and Analysis; Chapter 3 Design of Members; Chapter 4 Design of Connections; Chapter 5 Detailing and Fabrication; Chapter 6 Testing; Chapter 7 Structural

معرفی کتاب «Design of Latticed Steel Transmission Structures (ASCE 10-97).: General; Chapter 2 Loading, Geometry, and Analysis; Chapter 3 Design of Members; Chapter 4 Design of Connections; Chapter 5 Detailing and Fabrication; Chapter 6 Testing; Chapter 7 Structural» نوشتهٔ American Society of Civil Engineers (ASCE)، منتشرشده توسط نشر American Society of Civil Engineers; Brand: Amer Society of Civil Engineers; Amer Society of Civil Engineers در سال 2000. این کتاب در فرمت pdf، زبان انگلیسی ارائه شده است.

This updated standard, ''Design of Latticed Steel Transmission Structures (ASCE 10-97)'', provides requirements for the design of guyed and self-supporting latticed steel electrical transmission structures. They are applicable for hot-rolled and cold-formed steel shapes. Analysis techniques are outlined for the geometrical configurations presently in use. Procedures for the design of individual members reflect extensive experience and test data on steels with yield points up to 65 ksi. Connection design procedures allow the engineer to match connection capability to the most suitable end and edge distances for detailing. If full scale structure testing is required procedures are outlined to assist in obtaining critical information. Design procedures cover structural steel members and connections used in foundations. The commentary provides supporting background data This Standard provides requirements for the design of guyed and self-supporting latticed steel electrical transmission structures. The requirements are applicable for hot-rolled and cold-formed steel shapes. Analysis techniques are outlined for the geometrical configurations currently in use. Procedures for the design of individual members reflect extensive experience and test data on steels with yield points up to 65 ksi. Connection design procedures allow the engineer to match connection capability to the most suitable end and edge distances for detailing. If full-scale structure testing is required, procedures are outlined to assist in obtaining critical information. Design procedures cover structural steel members and connections used in foundations. The commentary provides supporting background data. This title is not available for download by the chapter Book by American Society of Civil Engineers
دانلود کتاب Design of Latticed Steel Transmission Structures (ASCE 10-97).: General; Chapter 2 Loading, Geometry, and Analysis; Chapter 3 Design of Members; Chapter 4 Design of Connections; Chapter 5 Detailing and Fabrication; Chapter 6 Testing; Chapter 7 Structural