BS EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (BS EN 61010-1:2010, IEC 61010-1:2010)
معرفی کتاب «BS EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (BS EN 61010-1:2010, IEC 61010-1:2010)» نوشتهٔ British Standards Institution, International Electrotechnical Commission، منتشرشده توسط نشر BSI British Standards Institution در سال 2010. این کتاب در فرمت pdf، زبان انگلیسی ارائه شده است.
BS EN 61010-1 is the UK implementation of IEC 61010-1. IEC 61010-1:2010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used. a) Electrical test and measurement equipment b) Electrical industrial process-control equipment c) Electrical laboratory equipment This third edition cancels and replaces the second edition published in 2001. It constitutes a technical revision. This edition includes the following significant changes from the second edition, as well as numerous other changes. - The scope of the standard has been expanded to include all locations where these products may be used, so that both professional and non-professional versions of these products are within the scope. - The requirements for testing and measuring circuits (in various subclauses and the entirety of Clause 16) have been removed and included in a particular standard IEC 61010-2-030. - Insulation requirements (6.7) have been completely rewritten. - Additional requirements for protection against mechanical HAZARDS (Clause 7) have been included. - Surface temperature limits (Clause 10) have been modified to conform to the limits of EN 563. - Radiation requirements (Clause 12) have been modified, and take into account a distinction between intended emission and unintended emission. - Requirements for reasonably foreseeable misuse and ergonomic aspects have been added (Clause 16). - A new clause (Clause 17) has been added to deal with HAZARDS and environments not covered by the standard, along with a new informative annex (Annex J) dealing with RISK assessment. - A new informative annex (Annex E) addresses methods of reducing the POLLUTION DEGREE of a micro-environment. - Requirements for the qualification of coatings for protection against POLLUTION have been added (Annex H). - A new informative annex (Annex I) has been added to further explain how to determine the WORKING VOLTAGE of a MAINS CIRCUIT. The contents of the corrigendum 1 of May 2011, the interpretation sheet 1 of February 2013 and the corrigendum 2 of October 2013 have been included in this copy. iec61010-1{ed3.0}b.pdf English CONTENTS FOREWORD INTRODUCTION 1 Scope and object 1.1 Scope 1.2 Object 1.3 Verification 1.4 Environmental conditions 2 Normative references 3 Terms and definitions 3.1 Equipment and states of equipment 3.2 Parts and accessories 3.3 Quantities 3.4 Tests 3.5 Safety terms 3.6 Insulation 4 Tests 4.1 General 4.2 Sequence of tests 4.3 Reference test conditions 4.4 Testing in single fault condition 5 Marking and documentation 5.1 Marking 5.2 Warning markings 5.3 Durability of markings 5.4 Documentation 6 Protection against electric shock 6.1 General 6.2 Determination of accessible parts 6.3 Limit values for accessible parts 6.4 Primary means of protection 6.5 Additional means of protection in case of single fault conditions 6.6 Connections to external circuits 6.7 Insulation requirements 6.8 Procedure for voltage tests 6.9 Constructional requirements for protection against electric shock 6.10 Connection to the mains supply source and connections between parts of equipment 6.11 Disconnection from supply source 7 Protection against mechanical hazards 7.1 General 7.2 Sharp edges 7.3 Moving parts 7.4 Stability 7.5 Provisions for lifting and carrying 7.6 Wall mounting 7.7 Expelled parts 8 Resistance to mechanical stresses 8.1 General 8.2 Enclosure rigidity tests 8.3 Drop test 9 Protection against the spread of fire 9.1 General 9.2 Eliminating or reducing the sources of ignition within the equipment 9.3 Containment of fire within the equipment, should it occur 9.4 Limited-energy circuit 9.5 Requirements for equipment containing or using flammable liquids 9.6 Overcurrent protection 10 Equipment temperature limits and resistance to heat 10.1 Surface temperature limits for protection against burns 10.2 Temperatures of windings 10.3 Other temperature measurements 10.4 Conduct of temperature tests 10.5 Resistance to heat 11 Protection against hazards from fluids 11.1 General 11.2 Cleaning 11.3 Spillage 11.4 Overflow 11.5 Battery electrolyte 11.6 Specially protected equipment 11.7 Fluid pressure and leakage 12 Protection against radiation, including laser sources, and against sonic and ultrasonic pressure 12.1 General 12.2 Equipment producing ionizing radiation 12.3 Ultraviolet (UV) radiation 12.4 Microwave radiation 12.5 Sonic and ultrasonic pressure 12.6 Laser sources 13 Protection against liberated gases and substances, explosion and implosion 13.1 Poisonous and injurious gases and substances 13.2 Explosion and implosion 14 Components and subassemblies 14.1 General 14.2 Motors 14.3 Overtemperature protection devices 14.4 Fuse holders 14.5 Mains voltage selection devices 14.6 Mains transformers tested outside equipment 14.7 Printed wiring boards 14.8 Circuits or components used as transient overvoltage limiting devices 15 Protection by interlocks 15.1 General 15.2 Prevention of reactivating 15.3 Reliability 16 Hazards resulting from application 16.1 Reasonably foreseeable misuse 16.2 Ergonomic aspects 17 Risk assessment Annexes Annex A (normative) Measuring circuits for touch current (see 6.3) Annex B (normative) Standard test fingers (see 6.2) Annex C (normative) Measurement of clearances and creepage distances Annex D (normative) Parts between which insulation requirements are specified (see 6.4 and 6.5.3) Annex E (informative) Guideline for reduction of pollution degrees Annex F (normative) Routine tests Annex G (informative) Leakage and rupture from fluids under pressure Annex H (normative) Qualification of conformal coatings for protection against pollution Annex I (informative) Line-to-neutral voltages for common mains supply systems Annex J (informative) Risk assessment Annex K (normative) Insulation requirements not covered by 6.7 Annex L (informative) Index of defined terms Bibliography Figures Figure 1 – Measurements through openings in enclosures Figure 2 – Maximum duration of short-term accessible voltages in single fault condition (see 6.3.2 a)) Figure 3 – Capacitance level versus voltage in normal condition and single fault condition (see 6.3.1 c) and 6.3.2 c)) Figure 4 – Acceptable arrangement of protective means against electric shock Figure 5 – Examples of binding screw assemblies Figure 6 – Distance between conductors on an interface between two layers Figure 7 – Distance between adjacent conductors along an interface of two inner layers Figure 8 – Distance between adjacent conductors located between the same two layers Figure 9 – Detachable mains supply cords and connections Figure 10 – Impact test using a sphere Figure 11 – Flow chart to explain the requirements for protection against the spread of fire Figure 12 – Baffle Figure 13 – Area of the bottom of an enclosure to be constructed as specified in 9.3.2 c) 1) Figure 14 – Ball-pressure test apparatus Figure 15 – Flow chart for conformity options 14.1 a), b), c) and d) Figure A.1 – Measuring circuit for a.c. with frequencies up to 1 MHz and for d.c. Figure A.2 – Measuring circuits for sinusoidal a.c. with frequencies up to 100 Hz and for d.c. Figure A.3 – Current measuring circuit for electrical burns Figure A.4 – Current measuring circuit for wet contact Figure B.1 – Rigid test finger Figure B.2 – Jointed test finger Figure C.1 – Examples of methods of measuring clearances and creepage distances Figures D.1a) to d) – Protection between hazardous live circuits and accessible parts Figures D.1e) to h) – Protection between hazardous live circuits and circuits which accessible external terminals Figures D.2 a) and D.2 b) – Protection between a hazardous live internal circuit and an accessible part which is not bonded to other accessible parts Figures D.2 c) and D.2 d) – Protection between a hazardous live primary circuit and circuits which have accessible external terminals Figure D.3 – Protection of external accessible terminals of two hazardous live circuits Figure G.1 – Conformity verification process (see G.2) Figure H.1 – Test sequence and conformity Figure J.1 – Iterative process of risk assessment and risk reduction Figure J.2 – Risk reduction Figure K.1 – Distance between conductors on an interface between two layers Figure K.2 – Distance between adjacent conductors along an interface of an inner layer Figure K.3 – Distance between adjacent conductors located between the same two layers Figure K.4 – Example of recurring peak voltage Tables Table 1 – Symbols Table 2 – Tightening torque for binding screw assemblies Table 3 – Multiplication factors for clearances of equipment rated for operation at altitudes up to 5 000 m Table 4 – Clearances and creepage distances for mains circuits of overvoltage category II up to 300 V Table 5 – Test voltages for solid insulation in mains circuits of overvoltage category II up to 300 V Table 6 – Clearances and test voltages for secondary circuits derived from mains circuits of overvoltage category II up to 300 V Table 7 – Creepage distances for secondary circuits Table 8 – Minimum values for distance or thickness (see 6.7.3.4.2 to 6.7.3.4.4) Table 9 – Distances between terminals and foil Table 10 – Correction factors according to test site altitude for test voltages for clearances Table 11 – Values for physical tests on cord anchorages Table 12 – Protective measures against mechanical hazards to body parts Table 13 – Minimum maintained gaps to prevent crushing for different body parts Table 14 – Maximum gaps to prevent access for different body parts Table 15 – Impact energy levels, test height and corresponding IK codes Table 16 – Acceptable perforation of the bottom of an enclosure Table 17 – Limits of maximum available current Table 18 – Values for overcurrent protection devices Table 19 – Surface temperature limits in normal condition Table 20 – Maximum temperatures for insulation material of windings Table 21 – Impulse withstand voltages for overvoltagecategory II Table C.1 – Dimensions of X Table E.1 – Environmental situations Table E.2 – Reduction of pollution degrees Table F.1 – Test voltages for routine tests of mains circuits Table G.1 – Test pressures for equipment with pressures above 14 Mpa Table H.1 – Test parameters, test conditions and test procedures Table I.1 – Line-to-neutral voltages for common mains supply systems Table J.1 – Severity of harm Table J.2 – Probability of harm Table J.3 – Risk category Table K.1 – Multiplication factors for clearances for equipment rated for operation at altitudes up to 5 000 m Table K.2 – Clearances and creepage distances for mains circuits of overvoltage category II above 300 V Table K.3 – Clearances and creepage distances for mains circuits of overvoltage category III Table K.4 – Clearances and creepage distances for mains circuits of overvoltage category IV Table K.5 – Test voltages for solid insulation in mains circuits of overvoltage category II above 300 V Table K.6 – Test voltages for solid insulation in mains circuits of overvoltage category III Table K.7 – Test voltages for solid insulation in mains circuits of overvoltage category IV Table K.8 – Test voltages for testing long-term stress of solid insulation in mains circuits Table K.9 – Minimum values for distance or thickness of solid insulation Table K.10 – Clearances and test voltages for secondary circuits derived from mains circuits of overvoltage category II above 300 V Table K.11 – Clearances and test voltages for secondary circuits derived from mains circuits of overvoltage category III Table K.12 – Clearances and test voltages for secondary circuits derived from mains circuits of overvoltage category IV Table K.13 – Creepage distances for secondary circuits Table K.14 – Minimum values for distance or thickness (see K.2.4.2 to K.2.4.4) Table K.15 – Clearance values for the calculation of K.3.2 Table K.16 – Test voltages based on clearances Table K.17 – Clearances for basic insulation in circuits having recurring peak voltages or working voltages with frequencies above 30 kHz Français SOMMAIRE AVANT-PROPOS INTRODUCTION 1 Domaine d'application et objet 1.1 Domaine d'application 1.2 Objet 1.3 Vérification 1.4 Conditions d'environnement 2 Références normatives 3 Termes et définitions 3.1 Appareils et états des appareils 3.2 Parties et accessoires 3.3 Grandeurs 3.4 Essais 3.5 Termes de sécurité 3.6 Isolation 4 Essais 4.1 Généralités 4.2 Séquence d'essais 4.3 Conditions de référence pour les essais 4.4 Essais en condition de premier défaut 5 Marquage et documentation 5.1 Marquage 5.2 Marquage des avertissements 5.3 Durabilité du marquage 5.4 Documentation 6 Protection contre les chocs électriques 6.1 Généralités 6.2 Détermination des parties accessibles 6.3 Valeurs limites pour les parties accessibles 6.4 Moyens principaux de protection 6.5 Moyens additionnels de protection en cas de condition de premier défaut 6.6 Connexion aux circuits externes 6.7 Exigences relatives à l'isolation 6.8 Procédure pour les essais de tension 6.9 Exigences relatives à la construction pour la protection contre les chocs électriques 6.10 Raccordement à la source d'alimentation réseau et connexion entre les parties de l’appareil 6.11 Sectionnement de la source d'alimentation 7 Protection contre les dangers mécaniques 7.1 Généralités 7.2 Arêtes tranchantes 7.3 Parties mobiles 7.4 Stabilité 7.5 Moyens de levage et de transport 7.6 Montage mural 7.7 Parties éjectées 8 Résistance aux contraintes mécaniques 8.1 Généralités 8.2 Essais de rigidité de l’enveloppe 8.3 Essai de chute 9 Protection contre la propagation du feu 9.1 Généralités 9.2 Elimination ou réduction de l’allumage à l’intérieur de l’appareil 9.3 Retenue du feu à l’intérieur de l’appareil s’il se déclare 9.4 Circuit à énergie limitée 9.5 Exigences pour les appareils contenant des liquides inflammables 9.6 Protection contre les surintensités 10 Limites de température de l’appareil et résistance à la chaleur 10.1 Limites de température des surfaces pour la protection contre les brûlures 10.2 Température des bobinages 10.3 Autres mesures de température 10.4 Réalisation des essais de température 10.5 Résistance à la chaleur 11 Protection contre les dangers des fluides 11.1 Généralités 11.2 Nettoyage 11.3 Déversement 11.4 Débordement 11.5 Electrolyte des piles et accumulateurs 11.6 Appareils spécialement protégés 11.7 Fluide sous pression et fuites 12 Protection contre les radiations, y compris les sources laser, et contre la pression acoustique et ultrasonique 12.1 Généralités 12.2 Appareil produisant un rayonnement ionisant 12.3 Rayonnement ultraviolet (UV) 12.4 Rayonnement hyperfréquence 12.5 Pression acoustique et ultrasonique 12.6 Sources laser 13 Protection contre les émissions de gaz et substances, les explosions et les implosions 13.1 Gaz et substances toxiques et nocifs 13.2 Explosion et implosion 14 Composants et sous-ensembles 14.1 Généralités 14.2 Moteurs 14.3 Dispositifs de protection contre les sur-températures 14.4 Porte-fusibles 14.5 Sélecteurs de tension réseau 14.6 Transformateurs d'alimentation réseau testés en dehors de l’appareil 14.7 Circuits imprimés 14.8 Circuits ou composants utilisés comme limiteurs de surtensions transitoires 15 Protection par systèmes de verrouillage 15.1 Généralités 15.2 Prévention de réactivation 15.3 Fiabilité 16 Dangers résultant de l'application 16.1 Mauvais usage raisonnablement prévisible 16.2 Aspects ergonomiques 17 Appréciation du risque Annexes Annexe A (normative) Circuits de mesure du courant de contact (voir 6.3) Annexe B (normative) Doigts d'épreuve normalisés (voir 6.2) Annexe C (normative) Mesure des distances d’isolement et des lignes de fuite Annexe D (normative) Parties entre lesquelles des exigences d'isolement sont spécifiées (voir 6.4 et 6.5.3) Annexe E (informative) Principes directeurs pour la réduction des degrés de pollution Annexe F (normative) Essais individuels de série Annexe G (informative) Fuite et rupture des fluides sous pression Annexe H (normative) Qualification des revêtements enrobant pour la protection contre la pollution Annexe I (informative) Tensions phase-neutre des réseaux de distribution généralement utilisés Annexe J (informative) Appréciation du risque Annexe K (normative) Exigences d’isolation non couvertes par 6.7 Annexe L (informative) Index des termes définis Bibliographie Figures Figure 1 – Mesures à travers les ouvertures des enveloppes Figure 2 – Durée maximale des tensions de courte durée accessibles en condition de premier défaut (voir 6.3.2 a)) Figure 3 – Niveau de la capacité en fonction de la tension en condition normale et en condition de premier défaut (voir 6.3.1 c) et 6.3.2 c)) Figure 4 – Organisation acceptable des moyens de protection contre les chocs électriques Figure 5 – Exemples de montages vissés Figure 6 – Distance entre conducteurs situés sur l’interface entre deux couches Figure 7 – Distance entre conducteurs adjacents situés sur l’interface entre deux couches internes Figure 8 – Distance entre conducteurs adjacents situés entre les deux mêmes couches Figure 9 – Cordons d'alimentation réseau amovibles et connexions Figure 10 – Essai d’impact utilisant une sphère Figure 11 – Diagramme expliquant les exigences pour la protection contre la propagation du feu Figure 12 – Chicane Figure 13 – Emplacement du fond d’une enveloppe à construire comme spécifié en 9.3.2 c) 1) Figure 14 – Appareil d’essai de pression à la bille Figure 15 – Diagramme des options de conformité 14.1 a), b), c) et d) Figure A.1 – Circuit de mesure du courant alternatif de fréquence jusqu'à 1 MHz et du courant continu Figure A.2 – Circuits de mesure du courant alternatif sinusoïdal de fréquence jusqu'à 100 Hz et du courant continu Figure A.3 – Circuit de mesure du courant pour brûlures électriques Figure A.4 – Circuit de mesure du courant pour contact en emplacement humide Figure B.1 – Doigt d'épreuve rigide Figure B.2 – Doigt d'épreuve articulé Figure C.1 – Exemples de méthodes de mesure des distances d’isolement et des lignes de fuite Figure D.1a) à Figure D.1d) – Protection entre des circuits sous tension dangereuse et des parties accessibles Figure D.1e) à Figure D.1h) – Protection entre des circuits sous tension dangereuse et des circuits qui ont des bornes externes accessibles Figure D.2a) et Figure D.2b) – Protection entre un circuit interne sous tension dangereuse et une partie accessible qui n'est pas reliée à d'autres parties accessibles Figure D.2c) et Figure D.2d) – Protection entre des circuits primaires sous tension dangereuse et des circuits qui ont des bornes externes accessibles Figure D.3 – Protection des bornes externes accessibles de deux circuits sous tension dangereuse Figure G.1 – Processus de vérification de la conformité (voir G.2) Figure H.1 – Séquence d’essai et conformité Figure J.1 – Processus itératif d’appréciation du risque et de réduction du risque Figure J.2 – Réduction du risque Figure K.1 – Distance entre conducteurs situés sur l’interface entre deux couches Figure K.2 – Distance entre conducteurs adjacents situés sur l’interface entre deux couches internes Figure K.3 – Distance entre conducteurs adjacents situés entre les deux mêmes couches Figure K.4 – Exemple de tension de crête répétitive Tableaux Tableau 1 – Symboles Tableau 2 – Couples de serrage pour les montages vissés Tableau 3 – Coefficients multiplicateurs pour des distances d’isolement pour les altitudes de fonctionnement assignées jusqu’à 5 000 m d’altitude Tableau 4 – Distances d’isolement et lignes de fuite des circuits réseau en catégorie de surtension II jusqu’à 300 V Tableau 5 – Tensions d'essai de l’isolation solide des circuits réseau en catégorie de surtension II jusqu’à 300 V Tableau 6 – Distances d’isolement et tensions d’essai des circuits secondaires dérivés des circuits réseau en catégorie de surtension II jusqu’à 300 V Tableau 7 – Lignes de fuite des circuits secondaires Tableau 8 – Valeurs minimales de la distance ou de l’épaisseur (voir 6.7.3.4.2 à 6.7.3.4.4) Tableau 9 – Distances entre les bornes et la feuille Tableau 10 – Coefficients de correction des tensions d’essai des distances d’isolement suivant l’altitude du site d’essai Tableau 11 – Valeurs des essais mécaniques sur les fixations de cordon Tableau 12 – Mesures de protection contre les dangers mécaniques des parties du corps Tableau 13 – Ecartements minimaux maintenus pour éviter l'écrasement de différentes parties du corps Tableau 14 – Ecartements maximaux pour empêcher l'accès à différentes parties du corps Tableau 15 – Énergie de choc, hauteur d’essai et codes IK correspondant Tableau 16 – Perforation acceptable du fond d’une enveloppe Tableau 17 – Limites du courant maximal disponible Tableau 18 – Valeurs pour les dispositifs de protection contre les surintensités Tableau 19 – Limites des températures de surface en condition normale Tableau 20 – Températures maximum des matériaux d’isolation des bobinages Tableau 21 – Tensions de chocs en catégorie de surtension II Tableau C.1 – Largeur de X Tableau E.1 – Situations environnementales Tableau E.2 – Réduction du degré de pollution Tableau F.1 – Tensions d’essai pour les essais individuels de série des circuits réseau Tableau G.1 – Pressions d’essai pour les appareils avec des pressions supérieures à 14 MPa Tableau H.1 – Paramètres d’essai, conditions de l’essai et procédures d’essai Tableau I.1 – Tensions phase-neutre des réseaux de distribution utilisés Tableau J.1 – Gravité du dommage Tableau J.2 – Probabilité du dommage Tableau J.3 – Catégorie du risque Tableau K.1 – Coefficient multiplicateur pour les distances d’isolement pour un fonctionnement jusqu’à 5 000 m d’altitude Tableau K.2 – Distances d’isolement et lignes de fuite des circuits réseau en catégorie de surtension II au-delà de 300 V Tableau K.3 – Distances d’isolement et lignes de fuite des circuits réseau en catégorie de surtension III Tableau K.4 – Distances d’isolement et lignes de fuite des circuits réseau en catégorie de surtension IV Tableau K.5 – Tensions d'essai de l’isolation solide des circuits réseau en catégorie de surtension II au-delà de 300 V Tableau K.6 – Tensions d'essai de l’isolation solide des circuits réseau en catégorie de surtension III Tableau K.7 – Tensions d'essai de l’isolation solide des circuits réseau en catégorie de surtension IV Tableau K.8 – Tensions d'essai des contraintes électriques de longue durée de l’isolation solide des circuits réseau Tableau K.9 – Valeurs minimum de la distance ou de l’épaisseur de l’isolation solide Tableau K.10 – Distances d’isolement et tensions d’essai dans les circuits secondaires dérivés des circuits réseau en catégorie de surtension II au-delà de 300 V Tableau K.11 – Distances d’isolement et tensions d’essai dans les circuits secondaires dérivés des circuits réseau en catégorie de surtension III Tableau K.12 – Distances d’isolement et tensions d’essai dans les circuits secondaires dérivés des circuits réseau en catégorie de surtension IV Tableau K.13 – Lignes de fuite des circuits secondaires Tableau K.14 – Valeurs minimales de la distance ou de l’épaisseur (voir K.2.4.2 à K.2.4.4) Tableau K.15 – Valeurs de la distance d’isolement pour le calcul de K.3.2 Tableau K.16 – Tensions d’essai en fonction des distances d’isolement Tableau K.17 – Distances d’isolement des circuits ayant des tensions de crête répétitives ou dont la fréquence de la tension de service est supérieure à 30 kHz
دانلود کتاب BS EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (BS EN 61010-1:2010, IEC 61010-1:2010)